| Test voltage |
10 kV |
| Ranges |
500 V: 10 kΩ to 2 TΩ
1000 V: 10 kΩ to 4 TΩ
2500 V: 10 kΩ to 10 TΩ
5000 V: 10 kΩ to 15 TΩ
10000 V: 10 kΩ to 25 TΩ |
| Fixed test voltages |
500 / 1000 / 2500 / 5000 / 10000 V |
| Variable test voltages |
40 V - 10000 V
3 presettable voltage values |
| Variable voltage settings |
Variable: 40-10 kV
Increment: 40 V - 1 kV: 10 V
1 kV - 10 kV: 100 V |
| Ramp mode |
3 Presettable ramps:
Start voltage / End voltage / Duration |
| Ramp configuration range |
40-1100 V / 500-10000 V |
| Step mode |
Up to 10 steps (value and duration configurable for each step) |
|
| Voltage measurement after test |
AC: 0 - 2500 V
DC: 0 - 4000 V |
| Capacitance measurement (> 500V) |
0.001-9.999µF / 10.00-49.99µF |
| Leakage current measurement |
0 - 8 mA |
| Discharge after test |
Yes / automatic |
| Additional test stop modes |
| I-limit |
Programmable 0.2 - 5 mA |
| Early-break |
di/dt |
| Timer |
Up to 99 minutes 59 seconds |
|
| Burning mode |
Burning - continuous testing |
| Ratio calculation |
PI, DAR, DD, SV, ΔR (ppm/V) |
| Calculation of R at ref. T° |
Yes |
| Measurement display filter |
3 filters with 3 time constants |
| Graphs on display |
R(t)+u(t); i(t); i(u) |
| Storage |
256 recordings, 80000 points R, U, I and date |
| Communication |
Optically isolated port for USB and RS232 links |
| PC Software |
DataView® |
| Power supply |
NiMH rechargeable batteries, 8 x 1.2 V / 4000 mAh charging by external voltage: 90-260 V 50/60 Hz |
| Electrical safety |
1000 V cat IV - IEC 61010-1 and IEC 61557 |
| Dimensions / weight |
L x P x H: 406 x 330 x 174 mm, 6 kg approx |